Thyristor
Thyristors are a kind of semiconductor device. They have the same
characteristics as solid-state components made of silicon, such as transistors and diodes. This,
at times, makes it difficult to distinguish between thyristors and the other products. There are
different types of thyristors available, and you can get some of the best products on Heatcon.
What differentiates one thyristor from another could be a small detail. These helps design
specific circuits. It is, therefore, necessary to know the features, drawbacks, and the
relationship of the thyristor with the circuit to make things work smoothly.
A thyristor has four layers, which alternate between the P-type and the N-type of
semiconductors. The most basic thyristors have three terminals. It includes the negative
terminal or cathode, the positive terminal or anode, and the gate terminal or the control
terminal. The thyristor primarily acts as a switch that controls the flow of electric power and
functions as a switch. The device is used in diverse electric circuits, ranging from power
transmission lines to something like alarms. Heatcon manufactures advanced and quality
thyristors used across a wide range of industries for different functions.
ANALOG THYRISTOR POWER CONTROLLERS HI-8003 -TP-C3-ED
Features
SOFT START & SOFT END: In soft start the output is given to the load in an exponential way. This character prevents excess inrush current to the heaters or transformers. This feature increases the life of the load.OVER-LOAD TRIP: OVER-LOAD trip can be adjustable from 110% to 200% of the rated output value. If OVER-LOAD occurs the output is disabled.
AUTOMATIC RESET: When OVER-LOAD trip happens, after three seconds delay thyristor again starts normally and provides output. If OVER-LOAD trip happens more than three times with in 10mins, the output is disabled permanently.
RESET SWITCH : If any problem occurs in the output or input, and output is disabled, then hootter goes on. At this stage rectify the problem and press the reset switch.
ENABLE SWITCH: Optional Enable Switch is also provided.
Specifications
SYSTEM INPUT : 3 PHASE 415VAC with Neutral , 50HZMODE OF CONTROL : PHASE ANGLE CONTROL
SCR CONFIGURATION : FULL CONVERTER SUITABLE FOR PHASE ANGLE CONTROL
TYPE OF LOAD : RESISTIVE / INDUCTIVE
POWER HANDLING : According to customers requirement(Maximum:100KW)
MAXIMUM LOAD CURRENT : 300A
CONTROLLING INPUT : 4-20mA(0-10VDC)
TYPE OF CONNECTION : STAR/DELTA
DIGITAL POWER CONTROLLERS – HI-8003-DP-C3
Features
SOFT START & SOFT END: In soft start the output is given to the load in an exponential way. This character prevents excess inrush current to the heaters or transformers. This feature increases the life of the load.OVER-LOAD TRIP: OVER-LOAD trip can be adjustable from 110% to 200% of the rated output value. If OVER-LOAD occurs the output is disabled.
AUTOMATIC RESET: When OVER-LOAD trip happens, after three seconds delay thyristor again starts normally and provides output. If OVER-LOAD trip happens more than three times with in 10mins, the output is disabled permanently.
RESET SWITCH : If any problem occurs in the output or input, and output is disabled, then hootter goes on. At this stage rectify the problem and press the reset switch.
ENABLE SWITCH: Optional Enable Switch is also provided.
DESCRIPTION
SYSTEM INPUT : 3 PHASE 415VAC , 50HZMODE OF CONTROL : PHASE ANGLE CONTROL
SCR CONFIGURATION : FULL CONVERTER SUITABLE FOR PHASE ANGLE CONTROL
TYPE OF LOAD : RESISTIVE / INDUCTIVE
POWER HANDLING : According to customers requirement
MAXIMUM LOAD CURRENT : 150 Amps
CONTROLLING INPUT : 4-20mA/0-10VDC
TYPE OF CONNECTION : STAR/DELTA
DIGITAL POWER REGULATOR – 2-PHASE, HI-8003 M
Features:
SOFT START & SOFT END: In soft start the output is given to the load in an exponential way. This character prevents excess inrush current to the heaters or transformers. This feature increases the life of the load.OVER-LOAD TRIP: OVER-LOAD trip can be adjustable from 110% to 200% of the rated output value. If OVER-LOAD occurs the output is disabled.
AUTOMATIC RESET: When OVER-LOAD trip happens, after three seconds delay thyristor again starts normally and provides output. If OVER-LOAD trip happens more than three times with in 10mins, the output is disabled permanently.
RESET SWITCH : If any problem occurs in the output or input, and output is disabled, then hootter goes on. At this stage rectify the problem and press the reset switch.
ENABLE SWITCH: Optional Enable Switch is also provided.
Specifications
SYSTEM INPUT : 2 PHASE 440VAC ±10% 50HZMODE OF CONTROL : PHASE ANGLE CONTROL
SCR CONFIGURATION : FULL CONVERTER SUITABLE FOR PHASE ANGLE CONTROL
TYPE OF LOAD : RESISTIVE / INDUCTIVE
POWER HANDLING : According to customers requirement(Maximum:30KW)
MAXIMUM LOAD CURRENT : 50A
CONTROLLING INPUT : 4-20mA(or0-10VDC)
HI-8003A40 – ANALOG THYRISTOR POWER CONTROLLER
Features:
SOFT START & SOFT END: In soft start the output is given to the load in an exponential way. This character prevents excess inrush current to the heaters or transformers. This feature increases the life of the load.OVER-LOAD TRIP: OVER-LOAD trip can be adjustable from 110% to 200% of the rated output value. If OVER-LOAD occurs the output is disabled.
AUTOMATIC RESET: When OVER-LOAD trip happens, after three seconds delay thyristor again starts normally and provides output. If OVER-LOAD trip happens more than three times with in 10mins, the output is disabled permanently.
RESET SWITCH : If any problem occurs in the output or input, and output is disabled, then hootter goes on. At this stage rectify the problem and press the reset switch.
ENABLE SWITCH: Optional Enable Switch is also provided.
Specifications
SYSTEM INPUT : 1 PHASE 230VAC ±10% 50HZMODE OF CONTROL : PHASE ANGLE CONTROL
SCR CONFIGURATION : FULL CONVERTER SUITABLE FOR PHASE ANGLE CONTROL
TYPE OF LOAD : RESISTIVE / INDUCTIVE
POWER HANDLING : According to customers requirement(Maximum:5KW)
MAXIMUM LOAD CURRENT : 40A
CONTROLLING INPUT : 4-20mA( 0-10VDC)
THYRISTOR BASED DIGITAL POWER CONTROLLER – HI-8003 M
Features:
SOFT START & SOFT END: In soft start the output is given to the load in an exponential way. This character prevents excess inrush current to the heaters or transformers. This feature increases the life of the load.OVER-LOAD TRIP: OVER-LOAD trip can be adjustable from 110% to 200% of the rated output value. If OVER-LOAD occurs the output is disabled.
AUTOMATIC RESET: When OVER-LOAD trip happens, after three seconds delay thyristor again starts normally and provides output. If OVER-LOAD trip happens more than three times with in 10mins, the output is disabled permanently.
RESET SWITCH : If any problem occurs in the output or input, and output is disabled, then hootter goes on. At this stage rectify the problem and press the reset switch.
ENABLE SWITCH: Optional Enable Switch is also provided.
Specifications
SYSTEM INPUT : 1 PHASE 230VAC ±10% 50HZMODE OF CONTROL : PHASE ANGLE CONTROL
SCR CONFIGURATION : FULL CONVERTER SUITABLE FOR PHASE ANGLE CONTROL
TYPE OF LOAD : RESISTIVE / INDUCTIVE
POWER HANDLING : According to customers requirement(Maximum:5KW)
MAXIMUM LOAD CURRENT : 40A
CONTROLLING INPUT : 4-20mA(or0-10VDC)
© 2020 Heatcon Sensors (P) Ltd..| All Rights Reserved.